Câble struct. libre 12 FO OS2 Vert INT/EXT Dca Câble d'intérieur/extérieur

Référence : R855640

Descriptif

Environmental Characteristics
Temperature cycling -30 C 70 C / -22 F +158 F
Temperature cycling acceptance criteria ?a = 0,15 dB, reversible
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -35 C 70 C / -31 F +158 F
Reversible temperature cycling acceptance criteria ?a = 0,05 dB after test
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -30 C to 70 C / -22 F to +158 F
Storage / Transport temperature -35 C to 70 C / -31 F to +158 F
Thermal load 0.59 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Flammability vertical cable bundle Pass
Flammability vertical cable bundle test method IEC 60332-3-22
Mechanical Data
In-service tensile strength 600 N
In-service tensile strength acceptance criteria ?a = 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 1800 N
Installation tensile strength acceptance criteria ?a = 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 1000 N/100mm
Long-term crush resistance acceptance criteria ?a = 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 2000 N/100mm
Short-term crush resistance acceptance criteria ?a = 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria ?a = 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle 180 , 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria ?a = 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 95 mm
Minimum bend radius during installation 130 mm
Technical Data
Cable family code UT1GF
Cable type Central loose tube cable
Cable version n.a.
Cable application universal use
CPR classification Dca-s2,d1,a1
DoP number D9013
Fiber type G.657.A1
Fiber count 12
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 1
Loose tube diameter 2,3 mm
Armor Intensified rodent protection
Outer sheath thickness 1,1 mm
Outer sheath material UV stable FRLSZH
Outer sheath color green
Cable outer diameter 6,2 mm
Cable weight 45.0 kg/km / 30 lbs/1000ft
DIN / VDE 0888 code U-DQ(ZN)BH
CPR classification Dca
Conditionnement : 1 ML divisible
Sur conditionnement : 1 conditionnement